A 5-part analyzer built around low-volume sampling
The Mindray BC-5150 performs a complete blood count with a 5-part white blood cell differential using flow cytometry together with tri-angle semi-conductor laser scatter and a chemical dye. It is specified at up to 60 samples per hour and reports 25 parameters with 3 histograms and 3 scattergrams.
RBC and PLT counting use improved DC impedance with a smaller 50 um diameter aperture. A narrower aperture improves resolution on low-platelet samples, a common difficulty when impedance counting is used on its own. Whole blood, capillary whole blood and prediluted modes are all supported, with 15 uL needed in whole-blood mode.
The instrument is operated entirely from its 10.4 inch TFT touch screen without an external PC, needs only three routine reagents with a two-year shelf life, and reports an NLR parameter in every CBC+DIFF result. LAN connectivity supports HL7 with bi-directional LIS, and up to 250,000 results are stored on board. ICEN supplies the BC-5150 to hospital laboratories, diagnostic centres and distributors, and confirms configuration and market requirements before quotation.
Applications
- Clinical laboratories
- Routine CBC and 5-part differential testing
- Low-platelet and pediatric sampling
- Laboratories without a dedicated PC at the bench
Who is this product for?
- Small and medium clinical laboratories
- Laboratories moving from 3-part to 5-part differential
- Pediatric and capillary sampling workflows
- Distributors supplying 5-part analyzers
Selected Product Highlights
Specifications below are presented from the current ICEN product catalog. Confirm final configuration and technical documents with our team before purchase.
CBC + 5-part WBC DIFF with 25 reported parameters
Semi-conductor laser scatter with flow cytometry and chemical dye
50 um counting aperture for improved low-PLT performance
15 uL whole-blood sampling; capillary mode supported
10.4 inch touch screen - fully operable without an external PC
Only three routine reagents, two-year shelf life; NLR in every result
Mindray BC-5150 Auto 5-Diff Hematology Analyzer - key specifications
| Brand | Mindray |
|---|---|
| Model | BC-5150 |
| Category | 5-part hematology analyzer |
| Test scope | CBC + 5-part WBC differential; whole blood, capillary whole blood and prediluted modes |
| Parameters reported | 25 reportable parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC; 12 research parameters (LIC%, LIC#, ALY%, ALY#, PLT Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%, Blast#, Blast%); 3 histograms (WBC, RBC, PLT) and 3 WBC differential scattergrams; NLR reported in every CBC+DIFF result |
| Throughput | 60 samples per hour |
| Sample volume | Whole blood mode 15 uL; capillary whole blood mode 15 uL; prediluted mode 20 uL (15 uL is ideal for pediatrics) |
| Sample handling | Open vial; whole blood, capillary whole blood (capillary sample run directly through the sample probe) and prediluted modes; no autoloader |
| Differential method | Flow cytometry (FCM) + tri-angle semi-conductor laser scatter + chemical dye method; dedicated optical counting channel for basophil measurement |
| Platelet counting | Improved DC impedance with a smaller 50 um diameter counting aperture, giving better performance on low-PLT samples; PLT linearity 0-5000 x10^9/L; precision <= 6.0% (100-149 x10^9/L) and <= 4.0% (150-500 x10^9/L); carryover <= 1.0% |
| Display | 10.4 inch TFT touch screen with wide viewing angle; all instrument operations can be completed on screen, practically eliminating the need for an external PC |
| Reagents | Only three routine reagents needed with 2 years shelf life (M-52D Diluent, M-52DIFF Lyse, M-52LH Lyse); plus Probe Cleanser; original QC and calibrator provided |
| Data storage | Up to 250,000 results including numeric and graphical information |
| LIS / connectivity | LAN port supports HL7 protocol; USB and LAN interfaces; bi-directional LIS with test results and patient information; 4 USB ports on the instrument left side (printer, keyboard, mouse, barcode scanner, etc.) |
| QC | Original QC and calibrator provided to ensure traceability and testing quality |
| Dimensions | Depth 400 mm x width 320 mm x height 410 mm |
| Weight | 24 kg |
If you are comparing 5-part analyzers, our buying guide sets out the selection criteria; the models below cover different throughput levels and sample volumes.
Common questions about Mindray BC-5150 Auto 5-Diff Hematology Analyzer
Does the BC-5150 provide a 5-part differential?
Yes. It performs CBC with a 5-part WBC differential using semi-conductor laser scatter, flow cytometry and a chemical dye.
How does the BC-5150 handle low-platelet samples?
RBC and PLT counting use improved DC impedance with a smaller 50 um diameter counting aperture, which improves resolution on low-PLT samples.
How much blood does the BC-5150 need?
15 uL in whole blood mode, 15 uL in capillary whole blood mode, and 20 uL in prediluted mode.
Does it need an external computer?
No. All instrument operation is carried out from the 10.4 inch touch screen.
What is the throughput of the BC-5150?
It is specified at up to 60 samples per hour.
Can ICEN provide a quotation?
Yes. Send the estimated quantity, destination market and required configuration through the Request a Quote button.
Related products and resources
Need a quotation or product configuration?
Send the model, estimated quantity, destination market and required configuration - our export team will reply with availability, documentation and pricing.