Mindray BC-10 product photo
3-Part Differential Analyzer

Mindray BC-10 Auto Hematology Analyzer

Mindray BC-10 auto hematology analyzer with a 3-part differential, 20 reported parameters and three histograms, in a compact benchtop format with a 10.4-inch touch screen.

Brand: Mindray   ·   Model: Mindray BC-10
ICEN supplies selected professional medical equipment. Product availability and market authorization vary by country.
Product Overview

A compact 3-part analyzer for small laboratories and clinics

The BC-10 is Mindray’s compact 3-part differential analyzer. It reports a CBC plus a three-part white cell differential in a single run and prints three histograms, which makes it suited to small laboratories, clinics and point-of-care sites that do not need a five-part differential.

Because the official specification sheet is complete for this model, every row in the table below is taken directly from Mindray’s published data — including throughput, sample volume, data storage and the reported parameter list.

Applications

  • Routine CBC and 3-part differential testing
  • Small and medium laboratories
  • Clinics and health centres
  • Mobile and outreach screening
  • Who is this product for?

  • Clinics and small laboratories
  • Distributors serving primary care
  • Laboratory networks adding sample capacity
  • Buyers who need a low sample volume
  • Key Features

    Selected Product Highlights

    Specifications below are presented from the current ICEN product catalog. Confirm final configuration and technical documents with our team before purchase.

    01

    Compact benchtop format

    A small-footprint analyzer for sites with limited bench space.

    02

    20 parameters and 3 histograms

    Reports CBC plus a 3-part differential, as published by Mindray.

    03

    Low sample volume

    Suited to paediatric and difficult-draw samples.

    04

    10.4-inch touch screen

    On-board operation with histogram display.

    05

    Local data storage

    Prints and stores results on board.

    06

    Complete official specification

    All published rows are listed below, with no placeholder values.

    Technical Specifications

    Mindray BC-10 – official specifications

    BrandMindray
    ModelBC-10
    Category3-part differential hematology analyzer; Auto Hematology Analyzer; CBC+3-DIFF
    Test scopeCBC+3-DIFF, 20 parameters + 3 histograms (histograms for WBC, RBC and PLT)
    Parameters reported20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR; 3 histograms for WBC, RBC and PLT
    Note (parameter count)Official Mindray documentation states 20 parameters + 3 histograms. Some third-party reseller listings state 22 parameters; 20 is the official figure.
    Throughput30 samples per hour (up to 30 samples per hour)
    Sample volumePrediluted mode: <=20 uL; Whole blood mode: <=9 uL
    Sample handling / autoloaderOpen vial sampling. No autoloader is offered for BC-10.
    Differential methodImpedance method for WBC, RBC and PLT counting
    Platelet countingImpedance method (PLT)
    ReagentsOnly three reagents needed; cyanide free reagent for hemoglobin test
    Display8.4 inch TFT Touch Screen
    Multi-languageChinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
    Data storageUp to 50,000 results including numeric and graphical information
    LIS / connectivityLAN port supports HL7 protocol; support bi-directional LIS. Interface: 4 USB ports (for external printer, software upgrade, barcode reader, external WIFI, keyboard and mouse), LAN port (1).
    QCOriginal QC, calibrators and reagents
    PrintoutThermal recorder, 50 mm wide paper, various printout formats
    Power supplyPower requirement: (100V-240V) +/-10%; <=180VA; (50Hz/60Hz) +/-1Hz
    DimensionsDepth 410 mm x width 300 mm x height 400 mm
    Weight<=20 kg
    Operating environmentTemperature: 15 C ~ 30 C; Humidity: 10% ~ 90%; Air pressure: 70kPa ~ 106kPa
    Regulatory / certificationsManufacturing processes are designed and managed in compliance with FDA, ISO and CE
    Official videono official video
    Hematology & laboratory scope

    Our buying guides set out how to compare differentials, throughput and reagent policy across the range; the analyzers below differ in differential depth, autoloader configuration and test menu.

    FAQ

    Questions buyers ask about the Mindray BC-10

    What is the difference between the BC-10 and the BC-20?

    Both are 3-part differential analyzers. The official BC-10 and BC-20 pages each publish their own throughput, sample-volume and parameter figures, and this page lists the BC-10 figures exactly as Mindray publishes them.

    How many parameters does the BC-10 report?

    Mindray’s official documentation states 20 reported parameters plus three histograms. Some reseller pages quote a different count, so we publish the official figure.

    Is the BC-10 a 5-part analyzer?

    No. The BC-10 is a 3-part differential analyzer. If you need a five-part differential, look at the BC-5150, BC-5380, BC-5390CRP or BC-760 on this site.

    Can we run the data through your LIS?

    The official specification lists bi-directional LIS connectivity. We confirm the interface configuration against your LIS before shipping.

    Does ICEN supply the official datasheet?

    Yes. Every specification on this page is taken from Mindray’s published documentation, and we send the datasheet with the quotation on request.

    Need a quotation or product configuration?

    Send the model, estimated quantity, destination market and required configuration - our export team will reply with availability, documentation and pricing.

    Chat with us