Mindray TV80 Transport Ventilator
Ventilator

Mindray TV80 Transport Ventilator

Mindray TV80 transport ventilator providing ICU-level ventilation for newborn to adult patients in a 6.5 kg body with a hot-swappable battery.

Brand: Mindray  ·  Model: Mindray TV80 Transport Ventilator
ICEN supplies selected professional medical equipment. Product availability and market authorization vary by country.
Product Overview

ICU-level ventilation in a 6.5 kg transport ventilator

The Mindray TV80 is a transport ventilator that delivers ICU-level ventilation for all types of patients, from newborns to adults, covering invasive ventilation, non-invasive ventilation and oxygen therapy. Its 6.5 kg body and hot-swappable battery address the portability and runtime requirements of a transport ventilator.

Battery operation is specified at >=11 hours, and the real-time battery display stays readable even when the unit is powered off, so remaining capacity can be checked before a transfer. Peak flow of >=260 L/min supports more effective non-invasive ventilation, and FiO2 is precisely adjustable from 21% to 100% using a non-consuming O2 sensor.

A dedicated proximal flow sensor measures tidal volume precisely with a minimum of 2 mL, which matters for neonatal and small paediatric patients. The TV80 also supports plug-and-play modular integration with a patient monitor and bedside-ventilator setting synchronization, with real-time O2 consumption monitoring. ICEN supplies the TV80 to hospitals, critical-care units and distributors, and confirms configuration, documentation and destination-market requirements before quotation.

Applications

  • ICU and critical-care ventilation
  • Invasive and non-invasive respiratory support, including oxygen therapy
  • Ventilation for newborn to adult patients
  • Respiratory care departments
  • Transport ventilation

Who is this product for?

ICU departmentsCritical care unitsRespiratory care departmentsHospitalsMedical equipment distributors
Key Features

Selected Product Highlights

Specifications below are presented from the current ICEN product catalog. Confirm final configuration and technical documents with our team before purchase.

01

Weighs only 6.5 kg; long-lasting hot-swappable battery with operating time >=11 hours and real-time battery display even when powered off

02

Peak flow >=260 L/min for more effective NIV support; FiO2 precisely adjustable from 21% to 100% with non-consuming O2 sensor

03

ICU-level ventilation for all types of patients, from newborns to adults, covering invasive ventilation, non-invasive ventilation and oxygen therapy

04

Dedicated proximal flow sensor measures tidal volume precisely with a minimum of 2 mL

05

Plug-and-play modular integration with patient monitor and bedside-ventilator setting synchronization; real-time O2 consumption monitoring

Technical Specifications

Mindray TV80 Transport Ventilator - key specifications

BrandMindray
ModelTV80
CategoryTransport ventilator
Weight6.5 kg
BatteryHot-swappable; operating time >=11 hours; real-time battery display even when powered off
Peak flow>=260 L/min, supporting more effective NIV
FiO2Precisely adjustable from 21% to 100%, with non-consuming O2 sensor
Patient rangeNewborn to adult
VentilationInvasive ventilation, non-invasive ventilation (NIV) and oxygen therapy
Tidal volume measurementDedicated proximal flow sensor, minimum 2 mL
IntegrationPlug-and-play modular integration with patient monitor and bedside-ventilator setting synchronization; real-time O2 consumption monitoring
Product Video

See Mindray TV80 Transport Ventilator in action

Watch the verified manufacturer video associated with this model.

Watch Video
ICU & Critical Care Solution

The TV80 is part of the wider ICU and critical-care equipment scope ICEN can supply and coordinate as one project, from transport and bedside ventilation to patient monitoring.

FAQ

Common questions about Mindray TV80 Transport Ventilator

What patient range does the Mindray TV80 support?

The TV80 covers all types of patients from newborns to adults, delivering ICU-level ventilation including invasive ventilation, non-invasive ventilation and oxygen therapy.

How long can the TV80 operate on battery?

The hot-swappable battery is specified with an operating time of >=11 hours, and the real-time battery display remains readable even when the unit is powered off.

Does the TV80 support non-invasive ventilation?

Yes. Peak flow of >=260 L/min is specified to support more effective non-invasive ventilation (NIV), alongside invasive ventilation and oxygen therapy.

How precisely can FiO2 be controlled?

FiO2 is precisely adjustable from 21% to 100% using a non-consuming O2 sensor, so oxygen concentration does not depend on a consumable sensor element.

What is the smallest tidal volume the TV80 can measure?

The dedicated proximal flow sensor measures tidal volume precisely with a minimum of 2 mL, which is relevant for neonatal and small paediatric patients.

Can the TV80 integrate with other equipment?

Yes. It supports plug-and-play modular integration with a patient monitor and bedside-ventilator setting synchronization, with real-time O2 consumption monitoring.

Need a quotation or product configuration?

Send the model, estimated quantity, destination market and required configuration - our export team will reply with availability, documentation and pricing.

Chat with us